* calibration-data.h
*
*/
/**********************************************************************************
Description: Constants for calibrating the serial interface
If the internal rc oscillator deviates too much from its nominal
frequency, the serial interface might not work correctly. In this
case you need to calibrate your Hacklace.
For calibration choose one of the following methods:
METHOD 1 - calibrate serial interface
Start your Hacklace so that the display is active. Measure the pulses
on pin 1 of the ISP connector with an oscilloscope or a frequency
counter. (Use ground potential (GND) on pin 6 of the ISP connector
as reference potential.) Measure the time from the rising edge of
one pulse to the rising edge of the next pulse. Enter the time
(in milliseconds) as T_MEASURED in this file.
METHOD 2 - calibrate main oscillator
You can use procedures described by Atmel to find an appropriate
OSCCAL value for calibrating the internal rc oscillator. Enter this
value as EXT_OSCCAL. See Atmel application notes for details.
License: This software is distributed under the creative commons license
CC-BY-NC-SA.
Disclaimer: This software is provided by the copyright holder "as is" and any
express or implied warranties, including, but not limited to, the
implied warranties of merchantability and fitness for a particular
purpose are disclaimed. In no event shall the copyright owner or
contributors be liable for any direct, indirect, incidental,
special, exemplary, or consequential damages (including, but not
limited to, procurement of substitute goods or services; loss of
use, data, or profits; or business interruption) however caused
and on any theory of liability, whether in contract, strict
liability, or tort (including negligence or otherwise) arising
in any way out of the use of this software, even if advised of
the possibility of such damage.
**********************************************************************************/
#ifndef CALIBRATION_DATA_H_
#define CALIBRATION_DATA_H_
/*************************
* calibration constants *
*************************/
// METHOD 1: calibrate serial interface
// Note: remove comment from following line if you want to use this method.
//#define T_MEASURED 5.00 // measured column cycle time (ms)
// METHOD 2: calibrate main oscillator
// Note: remove comment from following line if you want to use this method.
//#define EXT_OSCCAL 51
#endif /* CALIBRATION_DATA_H_ */